Rubber Flap Check Valve, Flanged GGG50
Contact HENGYA for Shipping, delivery, and payments information.
Products Category
Tag list
- 产品描述
-
What this valve does
The HC44X is a flanged check valve that lets water run one way and stops it coming back. It sits in a supply main, a pump discharge line or a district branch, and there is nothing to operate: no handle, no actuator, no electrical supply. Forward flow lifts the rubber flap off its seat; when the flow stops or reverses, the flap drops back and the returning pressure seals it shut.
Because the body is full bore and the only moving part is a single hinged flap, the valve adds very little resistance to the line and has almost nothing that can wear out of adjustment.
Construction
Body Ductile iron GGG50 (QT450-10), epoxy coated inside and out Top cover Ductile iron GGG50, bolted, with a gasket joint to the body Flap Rubber bonded to a steel insert plate, hinged on a through pin Seat Rubber faced, at an angle to the bore Hinge pin Stainless steel, retained in the body Coating Epoxy resin, internal and external, for potable and waste water duty The size, pressure rating and body material are cast into the side of the body, so what is on the pipe can be checked against the drawing without opening anything.
How the flap closes
The flap hangs on a hinge pin above the seat. In forward flow it is pushed clear of the bore and sits almost parallel to the flow, which keeps head loss low. When the flow slows, the flap falls under its own weight; the moment the line pressure turns around, water on the downstream side presses the rubber face onto the seat and holds it there.
The angled seat means the flap only has to travel a short distance before it lands, so the valve shuts before a full reverse flow can build up. That short travel is what keeps surge pressure down on pump discharge lines.
Technical specification
Model HC44X Nominal size DN40 - DN800 Nominal pressure PN10 / PN16 / PN25 Body material Ductile iron GGG50 (QT450-10) Flap material EPDM as standard; NBR on request Working medium Water, raw water, treated waste water Working temperature 0 - 80 °C Connection Flanged, ISO 7005 / EN 1092-2 Drive None - flow operated Pressure test Shell 1.5 x PN, seal 1.1 x PN to EN 12266-1 Pressure ratings
Parameter PN10 PN16 PN25 Nominal pressure (MPa) 1.0 1.6 2.5 Shell test pressure (MPa) 1.5 2.4 3.75 Seal test pressure (MPa) 1.1 1.76 2.75 Flange and face-to-face
Flange drilling meets EN 1092-2 for the pressure rating ordered. Face-to-face length and overall height for each size follow the drawing supplied with the quotation, so the valve can be set against the pipe schedule before it is made.
Installation
- Fits horizontal or vertical pipe; on vertical runs the flow must go upwards so the flap can fall closed
- Follow the arrow cast on the body - it points in the permitted flow direction
- Leave enough clearance above the top cover to lift it off for service
- No pipeline stress may act on the body after bolting up; support the pipe either side on large sizes
- Flush the line before commissioning so debris does not lodge under the flap
- On pump discharge, fit the valve downstream of the pump and upstream of the isolating valve
Maintenance
Undo the cover bolts and lift the top cover off: the flap and hinge pin come out through the opening without cutting the valve out of the line. Inspect the rubber face for cuts or embedded grit, check that the flap swings freely, then refit with a new cover gasket. There is no spring to reset and no guide to align.
Standards and certification
Face-to-face DIN 3202 F6 Flange dimensions ISO 7005 / EN 1092-2 Pressure testing EN 12266-1 Quality management ISO 9001, certificate no. 05325Q30683R1S Environmental management ISO 14001, certificate no. 05325E30489R1S Occupational health and safety ISO 45001, certificate no. 05325S30455R1S ISO 9001, ISO 14001 and ISO 45001 certificates are held by Hebei Hengya Technology Co., Ltd. and are valid until 19 October 2028.
Typical applications
- Pump discharge on water supply and boosting stations, stopping back-flow when a pump stops
- District metering and branch lines where return flow has to be blocked
- Raw water intake and transfer mains
- Treated waste water and drainage pumping mains
- HVAC circulating systems where a chiller or boiler must not see reverse flow
- Fire-fighting water supply, downstream of the main pump set
Contact Us
Rubber Flap Check Valve, Flanged GGG50
Contact HENGYA for Shipping, delivery, and payments information.
Products Category
Tag list